Transwell (Boyden Chamber) Cell
Migration Assay
I.
Reagents and Materials
1.
Transwell Unit:
Corning-Costar 3494 Transwell. PTFE membrane and polystyrene plate, 12 wells
plate, 3.0µm pore size membrane, pre-coated with collagen types I and IV. (Fisher Cat # 07-200-561).
2.
BSA media: DMEM,
0.1%BSA (Note: you can add P/S to the
media for long-term storage).
3.
Q-tips (cotton
swabs), 10%formalin, Hematoxylin, Permont
(Fisher).
II.
Transwell (Boyden
Chamber) Assay Using Soluble Chemoattractents
1.
Pre-warm BSA
media and Complete media at 37oC
2.
Prepare desired
concentration of chemoattractant solution with BSA
media (without FBS), for 12 wells
plate, 1ml/well will be enough.
3.
Harvest
migratory cells (e.g., in T-25): Trypsinize with 1ml Trypsin and resuspend cell in suspension
with 5ml complete media.
4.
Spindown ½ speed for 5min (table
top clinical centrifuge), remove the media, wash the cell pellet in BSA media
once; resuspend and adjust the concentration of the
cell pellet to 5X105/ml with BSA media. For 12well plate, you will
need 0.5-1ml/ transwell. (Note: cells in T25 flask are trypsinized and resuspended in a total of 6ml BSA media; and 0.2ml to 0.5ml
be sufficient for one 12mm transwell insert).
5.
Assemble transwell insert in the chamber of 12 wells transwell plate (contain 1ml chemoattractant
solution), make sure the solution touches the bottom surface of membrane and
get rid of bubbles.
6.
Add the migratory
cell mix (in 0.5ml to 1.0ml total volume) into the Transwell
insert; allow cells to migrate for 4 to 5 hours in the 37oC, 5%CO2
incubator.
7.
Remove insert
from the chamber. Turn chamber upside-down and gently submerge in PBS several times to remove unattached cells.
8.
Fix cells by
submerging insert in 10% formalin for 10min. Then wash with PBS once.
9.
Stain cells by
soaking insert in hematoxylin for 30min (or
overnight), then wash the insert gently several times with tap water to remove excess stain.
10. Remove cells from unmigrated
(top) side by gently scrapping this
side with a wet Q-tip/cotton swab. Make sure wiping all cells out in this (top)
side. Allow the membrane to dry.
11. Cut out membrane from insert with the migrated side
down to a glass slide. Add a few drops of Permont onto
the membrane and cover it with cover slide evenly.
12. Count migrated cells on a grid under high power
(e.g., x20 or x30). You usually need to
count
Note: This protocol is designed to test whether
pre-seeded cells in the bottom chamber (a.k.a., Chemoattractant
Producing Cells, CPCs) can express certain secreted
factors to attract cells in the top chamber (i.e., Transwell
insert).
1.
Plate CPCs in the bottom chamber (i.e., 12-well Transwell Plate) (Note:
In fact, the regular 12-well plate can accommodate the Transwell
insert as well) the day before the migration assay. Depending on your experiments, you can use
293 or
2.
In next morning
(e.g., around 10-11AM), pre-warm BSA media and Complete media at 37oC
incubator (Note: it is more desirable that
aliquots of the above media are pre-equilibrated in the 37C 5%CO2 incubator).
3.
Harvest
migratory cells (e.g., in T-25): Trypsinize with 1ml Trypsin and resuspend cell in suspension
with 5ml complete media.
4.
Spindown ½ speed for 5min (table
top clinical centrifuge), remove the media, wash the cell pellet in BSA media
once; resuspend and adjust the concentration of the
cell pellet to 5X105/ml with BSA media. For 12well plate, you will need 0.5-1ml/ transwell. (Note:
cells in T25 flask are trypsinized and resuspended in a total of 6ml BSA media; and 0.2ml to 0.5ml
be sufficient for one 12mm Transwell insert).
5.
Assemble transwell insert in the chamber of 12 wells transwell plate (containing 1ml chemoattractant
medium produced by the bottom layer CPCs) (Note: do not change the overnight medium
already in the well); Make sure the solution touches the bottom surface of
membrane and get rid of bubbles.
6.
Add the
migratory cell mix (in 0.5ml to 1.0ml total volume) into the transwell insert; allow cells to migrate for 4 to 5 hours
in the 37oC, 5%CO2 incubator.
7.
Remove insert
from the chamber. Turn chamber upside-down and gently submerge in PBS several
times to remove unattached cells.
8.
Fix cells by
submerging insert in 10% formalin for 10min. Then wash with PBS once.
9.
Stain cells by
soaking insert in hematoxylin for 30min (or
overnight); then wash the insert gently
several times with tap water to remove excess stain.
10. Remove cells from unmigrated
(top) side by gently scrapping this
side with a wet Q-tip/cotton swab. Make sure wiping all residual cells out in
this (top) side. Allow the membrane to
dry.
11. Cut out membrane from insert with the migrated side
down to a glass slide. Add a few drops of Permont onto
the membrane and cover it with cover slide evenly.
12. Count migrated cells on a grid under high power
(e.g., x20 or x30). You usually need to
count